Belden GUMXA12 Specifications
Product Overview
Environmental Space: Indoor/Outdoor – Euroclass Eca
Suitable Applications: For outdoor and indoor use in structured (data) wiring systems such as industrial backbone, campus backbone, building backbone (riser) and/or horizontal cabling. Suitable for networks in industrial, telecom, cable TV, and broadcast. Supports all computer network applications including FDDI, Gigabit Ethernet, and ATM.
Construction Details
Fiber Cable Construction
- Fiber Type: OS2
- Fiber Grade acc. ITU-T: G.652D & G.657A1
- Fiber Count: 12
Fiber Color Coding: TIA coding (Gxxxxxx.T): Blue, Orange, Green, Brown, Gray, White, Red, Black, Yellow, Violet, Pink, Aqua
Buffer Specification
- Fiber Type: OS2
- Buffer Construction: Tight
- Buffer Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
- Buffer Diameter: 0.9 mm
Cable Core Water Tight: Yes
Cable Core Waterblocking: Waterblocking Glass Yarns
Bulk Cable Weight: 148 kg/km
Jacket Specifications
- Number of Jackets: Double Jacket
- Type of Armor: Corrugated Steel Tape
Inner Jacket Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
Outer Jacket Specifications:
- Outer Jacket Material: LSZH – Low Smoke Zero Halogen (Flame Retardant)
- Nominal Diameter: 11.5 mm
- Ripcord: Yes
Table Notes: Standard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green
Optical Characteristics
- Max. Attenuation at 1310 nm: 0.40 dB/km
- Max. Attenuation at 1550 nm: 0.30 dB/km
- Max. Attenuation at 1625 nm: 0.30 dB/km
Belden GUMXA12 Mechanical Characteristics
Mechanical Tests
- Cable Min. Bend Radius Installation (Short Term): 230 mm (IEC 60794-1-21-E6, IEC 60794-2-20)
- Cable Min. Bend Radius Operation (Long Term): 172.5 mm (IEC 60794-1-21-E11, IEC 60794-2-20)
- Cable Max. Tensile Strength Installation (Short Term): 1500 N (337 lbf) (IEC 60794-1-21-E1, IEC 60794-2-20)
- Cable Max. Tensile Strength Operation (Long Term): 500 N (112 lbf) (IEC 60794-1-21-E1)
- Cable Max. Crush Resistance Installation (Short Term): 22 kN/m (IEC 60794-1-21-E3, IEC 60794-2-20)
- Cable Max. Crush Resistance Operation (Long Term): 11 kN/m (IEC 60794-1-21-E3, IEC 60794-2-20)
Temperature Range
- Operating Temperature Range: -20 °C to +70 °C
- Installation Temperature Range: -5 °C to +50 °C
- Storage Temperature Range: -30 °C to +70 °C
Product Material
- UL Rating/Flame Test: Non-UL Rated
Standards
- IEC Flammability: IEC 60332-1-2
- Reaction to Fire – Bundle Flame Test: IEC 60332-3-22
- IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: 10 µS/mm
- IEC 60754-1 – Halogen Amount: Zero
- IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: 4.3
- IEC 61034-2 – Smoke Density Min. Transmittance: 60%
- CPR Euroclass: Eca
- REACH: Compliant
- ISO/IEC Compliance: IEC 60794
- UV/ Sunlight Protection: Yes
History
- Revision Number: 0.180
- Revision Date: 05-16-2024
- Datasheet
Belden GUMXA12 Part Numbers
- GUMXA12.002100: Black, Reel, 2,100 m, EAN: 8719605081513

Reviews
There are no reviews yet.